    在传统四位置寻北方案基础上,针对光纤陀螺寻北仪提出了一种新的转位方案,将传统水平面内相互垂直转动寻北改为Ψ型转动寻北。相对传统转位方案,不仅保持了原有的优势,同时能够减少25%的转位时间。在不同情况下,通过巧妙的公式构造和选取对应位置下的陀螺输出,能有效避免光纤陀螺死区造成的寻北误差,并且可以提高某些特定角度范围的寻北精度。

    Abstract:

    On the basis of the traditional fourposition north seeker scheme,a new transposition scheme for the optical fiber gyroscope north seeker is proposed in this paper.The ψtype transposition scheme is used instead of the conventional perpendicular transposition scheme in horizontal plane.Compared with the traditional scheme, it not only maintains the original advantage,but also can reduce the transfer time by 25%.Under different circumstances,the error caused by the dead zone of FOG can be avoided effectively by using the formula constructed skillfully and selecting the corresponding position of the gyroscope output.And it can improve the accuracy of the north seeker in certain angle range.